NEW! Gas Quiksert models are now available from Blancett!

The Blancett QuikSert In-line Turbine Flow Meter provides the high accuracy and rigorous design of the standard Blancett turbine, but in a wafer-style mounting configuration. With a unique "between-the-flange" design, the need for mating flanges is eliminated, saving installation time and cost, and allowing for limited space requirements. The meter features a 316 stainless steel housing and rotor support, CD4MCU stainless steel rotor, and abrasion-resistant tungsten carbide rotor shaft and bearings. For fluid models, precision upstream and downstream flow straighteners ensure a high degree of measurement accuracy.
Click here to download the QuikSert Flow Meter Technical Data Sheet (1.06 MB).
Click here to download the Quicksert Gas Flow Meter Technical Data Sheet (2.1 MB).

Fluid and gas passes through a turbine, causing the turbine to rotate at a speed proportional to velocity. As each turbine blade passes through the magnetic field generated by the meter's magnetic pick-up, an AC voltage pulse is generated. These pulses provide an output frequency that is proportional to volumetric flow..
Click here to view a
short animation of the operating principle.
| Accuracy(Fluid): |
±1% of reading for 7/8" and larger meters;
±1% of reading over the upper 70% of the measuring range for 3/8",
1/2" and 3/4" meters |
| Accuracy(Gas): |
±2% of reading over the specified measuring range |
| Repeatability: |
±0.1%(Fluid),±0.5%(Gas), |
| Operating Temperature: |
-150 °F to +350 °F (-101 °C to +177 °C) (Fluid Standard)
Temperatures to +425 °F (+232 °C) (Fluid with high-temp pick-up)
-40 to +330 °F (-40 to +330 °C) (Gas) |
| Turndown Ratio: |
About 10:1 |
| End Connections: |
Wafer-style, ASME/ANSI B16.5-1996 |

Click here to view Canadian Registration Numbers (CRN)
| Part Number |
Meter Size x Flange Size |
Flow Ranges GPM |
Flow Ranges BPD |
Typical K-factor pulses/gallon |
| B131-038 |
3/8" x 1" |
0.60 - 3.00 |
20-100 |
18,000 |
| B131-050 |
1/2" x 1" |
0.75-7.50 |
25-250 |
13,000 |
| B131-075 |
3/4" x 1" |
2.0-15.0 |
68-515 |
3,300 |
| B131-088 |
7/8" x 1" |
3.0-30.0 |
100-1000 |
3,100 |
| B131-100 |
1" x 1" |
5.0-50.0 |
170-1700 |
870 |
| B132-050 |
1/2" x 2" |
0.75-7.50 |
25-250 |
13,000 |
| B132-075 |
3/4" x 2" |
2.0-15.0 |
68-515 |
3,300 |
| B132-088 |
7/8" x 2" |
3.0-30.0 |
100-1000 |
3,100 |
| B132-100 |
1" x 2" |
5.0-50.0 |
170-1700 |
870 |
| B132-150 |
1-1/2" x 2" |
15-180 |
515-6000 |
310 |
| B132-200 |
2" x 2" |
40-400 |
1,300-13,000 |
48 |
| B133-300 |
3 x 3" |
60-600 |
2,100-21,000 |
57 |
| B134-400 |
4" x 4" |
100 - 1,200 |
3,400 - 41,000 |
29 |
| B136-600 |
6" x 6" |
200 - 2,500 |
6,800 - 86,000 |
7 |
| B138-800 |
8" x 8" |
250 - 3,500 |
8,500-120,000 |
3 |
| B139-900 |
10" x 10" |
500 - 5,000 |
17,150-171,500 |
1.6 |
| Gas Part Number* |
Meter Size x Flange Size** |
Flow Ranges ACFM |
Flow Ranges MCFD |
Typical K-factor pulses/ft3 (pulses/m3) |
| B142-20L |
2" x 2" |
7 – 70 |
10 – 100 |
365 (12,900) |
| B142-20M |
2" x 2" |
14 – 210 |
20 – 300 |
190 (6,710) |
| B142-20H |
2" x 2" |
35 - 350 |
50 - 500 |
85 (3,000) |
*Does not include magnetic pickup. Order Blancett B111113 Low Drag Pickup